LNOTE
Name
Valid Value List
LNOTE NAME
WN Target analyte was detected in the method blank at or above the reporting limit.
WO Background subtracted from the QC samples and the client's sample(s).
WP Spike amount added < 30% of base concentration
WQ Duplicate precision calculation not required, base concentration < 3X MDL
WR The positive result is an atypical pattern for analysis.
WS Gasoline range compounds having broad peaks are significant.Possibly biologically altered gasoline.
WT Strongly aged gasoline or diesel range compounds are significant.
WU Unidentified peak(s) present.
WV Diesel range compounds are significant.
WX Gasoline range compounds are significant.
WY Oil range compounds are significant.
WZ Medium boling point pattern that does not match diesel.
XA No recognizable pattern.
XB Heavier gasoline range compounds are significant. Possilbly aged gasoline.
XC Total Threshold Limit Concentration (TTLC)
XD Sample diluted due to high organic content.
XE Liquid sample that contains greater than 5 volume % sediment.
XF Possible aged fuel.
XG Lighter than water immiscible sheen is present.
XH High bias in QC sample does not affect result since analyte not detected or below reporting limit.
XI Hydrocarbon response in motor oil range but does not resemble motor oil.
XJ Hydrocarbon response in Stoddard solvent range but does not resemble Stoddard solvent.
XK Outside client's test acceptance limits, but within laboratory calculated QC limits.
XL Elevated detection limits do not meet llimits specified in QAPP.
XM MS/MSD RPD exceeds control limits due to sample size difference.
XN MS RPD Fail and Sample Size Diff >10%.
XO The compound co-eluted with other compounds
XP The compound co-eluted with PCB-156
XQ The concentration of the analyte is an estimated value above the calibration range of the instrument
XR The concentration is less than 5% of the sample result, which is neglible according to the method
XT Sample was received unpreserved. Sample preserved by the laboratory prior to preparation.
XV Sample acidified to pH <2 and allowed to sit 24 hours before further processing.
XW Purged
XY Capped and allowed to equilibrate 24 hrs before sampling.
XZ No sample taken due to damaged probe.
YA Cation and anion sum
YB Not Requested/Not Required.
YC Dissociated ions may elevate this value (Ca+2, SO4-2 etc.)
YD Excluding barite, Ba SO4.
YE Excluding molybdenum disulfide, MoS2
YF Sample fails ion ratio criteria high.
YG Sample fails ion ratio criteria low.
YH Value less than reporting limit; may be estimated or non-detect.
YJ No sample was taken due to lack of access.
YK Reporting limit increased due to sample foaming.
YL Sample oxidized in the sample bottle with BrCl within 28 days of collect (extends hold time 90 days)
YM Liquid sample that contains greater than 1 volume % sediment.
YN Vials combined due to silt content.
YO Associated BS outside control limits high.
YP Associated CCV outside of control limits low.
YQ Associated CCV outside of control limits high.
YR Associated BS outside control limits low.
YS Associated ICV outside of control limits high.
YT Associated ICV outside of control limits low.
YU Associated Initial Calibration outside control limits (%RSD > 15%).
YV Outside of Control Limits.
YW Outside control limits due to high level in sample relative to spike amount.
ZD Result obtained from the analysis of a diluted sample.
ZM Estimated maximum possible concentration.

If you notice an error or omission in the valid value list or anywhere on this site, please contact us at help@edfhelpdesk.com - Thank you!